№ | № RD | Name of the characteristic being defined | What to sample for | Sampling speed | Sampling time | Shelf life | Note | |||||||||
1 | GOST 17.2.4-05 | suspended substances (dust) | AFA-VP filter | 75 dm3/min | At the end of sampling the total volume of air passed is recorded. | - | - | |||||||||
2 | RD 52.04.792-14 (FR.1.31.2015.19877) | Nitrogen dioxide | two series-connected ST 412 and a desiccant and ST-oxidizer located between them | 0, 5dm3/min | 30 | 10 days | When determining single concentration of nitrogen oxide and nitrogen dioxide: attach system consisting of two series-connected ST 412 and located between them along the air flow: a column filled with 10 cm of desiccant, and ST-oxidizer. When sampling, the column and sorption tubes should be fixed vertically with a layer of sorbent down. Air must pass from the bottom up.All connections are made with rubber couplings end-to-end. When determining the daily concentration of nitrogen oxide and nitrogen dioxide from a single sample, the test air is aspirated discretely, twelve times in 1 day for 20 minutes at regular intervals with a flow rate of 0.3 dm/min through a system consisting of two series-connected ST 412, prepared for selection and located between them along the air flow: a column filled with 100 cm of desiccant, and ST-oxidizer. When sampling columns and sorption tubes should be strengthened in a vertical position with a layer of sorbent down. Air must pass from the bottom up. All connections are made with rubber couplings end-to-end. Sampling can be carried out at the temperature of the air passing through the sorption tube from minus 10°C to 40°C. In the absence of sorption tubes ST 412 instead of each of them, the scheme includes two sorption tubes ST 212. |
|||||||||
Nitrogen oxide | ||||||||||||||||
3 | RD 52.04.791-14 (FR.1.31.2015.19887) | Ammonia | sorption tube | 2.0 dm3 / min | 20 | 5 days | Sorption tube should be fixed vertically with a layer of sorbent down. In order to delay the aerosol of ammonium salts during sampling, a filter holder with an AFA-VP-10 filter is connected to the sorption tube at the air inlet. All connecting tubes must be made of fluoropolymer and connected end-to-end with clean (washed and dried) rubber couplings. Care must be taken to ensure that the inner surface of the connecting tubes is dry to avoid ammonia sorption in them. Air must pass from the bottom up. Sampling can be carried out at the temperature of the air passing through the sorption tube from 0°C to 40°C. |
|||||||||
4 | MUK 4.1.596-96 | Ammonium sulphate (as ammonium ion) | AFA or " Sinyaya lenta" | 20 dm3/min | 10-20 | 7 days | - | |||||||||
Ammonium persulphate (as ammonium ion) | 1 day | |||||||||||||||
5 | RD 52.04.797-14 (FR.1.31.2015.19878) | Hydrogen fluoride (hydrofluoride) | sorption tube | 3 dm3/min | 20 | 7 days | When sampling, sorption tube should be strengthened in a vertical position with a layer of sorbent down. Air must go up from the bottom. Sampling can be performed at the temperature of the analyzed air from minus 10°C to 40°C. A filter holder with a filter for capturing solid fluorides and other aerosols is installed in front of the sorption tube using a polyethylene corner. Sorption tube, corner and filter holder must be connected end-to-end, so that there is no contact of air with the rubber. When determining daily concentrations, at least four single samples are taken at regular intervals. | |||||||||
6 | RD 52.04.793-14 (FR.1.31.2015.19882) | Hydrogen fluoride (hydrofluoride) | AFA-PV-10 filter and sorption tube | 4 dm3/min | 20 | 10 days | Filter holder with the filter and the sorption tube are connected by a rubber coupling end-to-end. Sorption tube should be fixed vertically with a layer of sorbent down. Air must flow from the bottom up. Sampling can be performed at the temperature of the analyzed air passing through the sorption tube, from 0°C to 40°C. At the expected concentrations of hydrogen chloride from 5 to 10 MPC, the volume air flow should be reduced to 2 dm/min. When determining daily concentration, at least four single samples are taken at regular intervals. |
|||||||||
7 | RD 52.04.795-14 (FR.1.31.2015.19886) | Hydrogen sulfide (dihydrosulfide) | sorption tube | 4 dm3/min | 20 | 2-3 days | When selecting sorption tube should be strengthened in a vertical position with a layer of sorbent down and protected from light by a screen made of black paper or foil. | |||||||||
8 | RD 52.04.794-14 (FR.1.31.2015.19884) | Sulfur dioxide | Richter absorbers | 2,5 dm3/min | 20 | 7 days | In case of high expected mass concentrations of sulfur dioxide, air consumption can be reduced to 0.5 dm/min. When determining daily concentrations, at least four single samples are taken at regular intervals. Sampling can be carried out at the temperature of the analyzed air from 0°C to 40°C. Samples must be protected from direct sunlight during sampling and storage. | |||||||||
9 | RD 52.04.831-15 (FR.1.31.2016.23390) | Soot (carbon-containing aerosol) | AFA-HP-10 AFA-VP10 | 20 дм3/мин | 30 | unlimited | Sampling is carried out on the windward side at a height of 1.5 m from the ground surface. | |||||||||
10 | RD 52.04.798-14 (FR.1.31.2015.19880) | chlorine | Richter absorber | 0,5 dm3/min | 20 | 3 days | When determining daily concentration, at least four single samples are taken at regular intervals. | |||||||||
11 | MUK 4.1.615-96 | Potassium chloride | AFA-VP-20 | 10 dm3/min | 12.5 | 1 month | - | |||||||||
12 | MUK 4.1.1044 a-01 | Dimethyamine | at the same time on 2 sorption tubes (sorbent Chromosorb 106 or 103) | 0,2 dm3/min | 10 | 3 days | Air is aspirated through a pre-cooled to 0°C outlet of a sorption tube. | |||||||||
Diethylamines | ||||||||||||||||
Propylamines | ||||||||||||||||
Triethylamines | ||||||||||||||||
Ethylamines | ||||||||||||||||
Dimethylformamide | ||||||||||||||||
13 | GOST R ISO 16017-1 | Acetonitrile | sorption tube-concentrator (TENAX sorbent) | (1-10) dm3/min | Depending on the conditions | 8 hours (or sorption tubes are placed in a clean, uncoated, airtight container. | - | |||||||||
Acrylonitrile (prop-2-isonitrile) | ||||||||||||||||
Hexane | ||||||||||||||||
Heptane | ||||||||||||||||
Decane | ||||||||||||||||
Dodecane | ||||||||||||||||
Nonane | ||||||||||||||||
Octane | ||||||||||||||||
Aliphatic saturated hydrocarbons of the gasoline fraction C6-C12 | ||||||||||||||||
Undecane | ||||||||||||||||
Acetone (propan-2-one) | ||||||||||||||||
Methylethyl ketone (Butanone) | ||||||||||||||||
Hexanon | ||||||||||||||||
Diacetone alcohol (4-hydroxy-4-methyl-2-pentanone) | ||||||||||||||||
Cyclohexanone | ||||||||||||||||
Benzene | ||||||||||||||||
Isopropylbenzene (Cumene) | ||||||||||||||||
Xylene (dimethylbenzene) | ||||||||||||||||
Pseudocumene (1,2,4-trimethylbenzene) | ||||||||||||||||
Styrene (ethenylbenzene) | ||||||||||||||||
Toluene (methylbenzene) | ||||||||||||||||
Ethylbenzene | ||||||||||||||||
Vinyl chloride (chloroethene) | ||||||||||||||||
Dichloromethane | ||||||||||||||||
1.1-dichloroethylene | ||||||||||||||||
Trichloroethane | ||||||||||||||||
Trichloroethylene | ||||||||||||||||
Carbon tetrachloride (tetrachloromethane) | ||||||||||||||||
Chlorobezene | ||||||||||||||||
Chloroform (trichloromethane) | ||||||||||||||||
Butanol | ||||||||||||||||
1.2-dichloroethane | ||||||||||||||||
GOST R ISO 16017-1 | Isobutanol | sorption tube-concentrator (TENAX sorbent) | (1-10) dm3/min | Depending on the conditions | 8 hours (or sorption tubes are placed in a clean, uncoated, airtight container. | - | ||||||||||
(2-methylpropan-1-ol) | ||||||||||||||||
Methanol (carbinol) | ||||||||||||||||
Amyl alcohol (pentanol) | ||||||||||||||||
Propyl alcohol (propan-1-ol) | ||||||||||||||||
Cyclohexanol (cyclohexyl alcohol) | ||||||||||||||||
Ethanol (ethyl alcohol) | ||||||||||||||||
Phenol (hydroxybenzene) | ||||||||||||||||
Butylacetate | ||||||||||||||||
Dibutylphthalate | ||||||||||||||||
Dimethylphthalate | ||||||||||||||||
Dimethylisophthalate | ||||||||||||||||
Diethylphthalate | ||||||||||||||||
Isobutylacetate | ||||||||||||||||
Methylacetate | ||||||||||||||||
Propylacetate | ||||||||||||||||
Vinylacetate (Ethenylacetate) | ||||||||||||||||
Ethylacrylate | ||||||||||||||||
Ethylacetate | ||||||||||||||||
14 | MUK 4.1.629-96 | Nitriles (C10-C16) | Yavorovskaya absorption device | 10 dm3/min | 30 | 5 hours | - | |||||||||
15 | FR.1.31.2011.11272 (M-22) | Butadiene (buta-1,3-diene) | 2 series-connected (end-to-end) sorption concentrator tubes (TENAX sorbent) | 0,3 dm3/min | 30 | 2 days in refrigerator | When determining surface concentration of a substance in the atmosphere, samples are taken at an altitude of 1.0 - 3.5 m from the earth's surface.Each sample is taken on 2 sequentially connected (end-to-end) sorption tubes installed vertically, with the inlet opening down.At expected mass concentrations not exceeding 1 mg/m3, sampling is performed with a volume flow rate of 0.3 dm3/min for 30 minutes. If the expected mass concentrations exceed 1 mg/m3, several samples are taken (2 - 3) with a lower volume flow rate during this time period. | |||||||||
Benzaldehyde | ||||||||||||||||
Methylacetate | ||||||||||||||||
Isopropyl acetate (1-methyethyl acetate) | ||||||||||||||||
n-propylacetate | ||||||||||||||||
isobutylacetate | ||||||||||||||||
N-Butylacetate | ||||||||||||||||
N-Amylacetate | ||||||||||||||||
Isoprene | ||||||||||||||||
N-Hexanol | ||||||||||||||||
2-Ethylhexanol | ||||||||||||||||
Octan-1-ol (n-oktyl alcohol) | ||||||||||||||||
Benzyl alcohol (benzyl carbinol) | ||||||||||||||||
Propionic acid | ||||||||||||||||
Pentanoic acid (valeric) | ||||||||||||||||
Hexanoic acid (capronic) | ||||||||||||||||
2-ethoxyethyl ether of acetic acid | ||||||||||||||||
FR.1.31.2011.11272 (M-22) | Methylcellosolve (2-methoxyethanol) | 2 series-connected (end-to-end) sorption concentrator tubes (TENAX sorbent) | 0,3 dm3/min | 30 | 2 days in refrigerator | When determining surface concentration of a substance in the atmosphere, samples are taken at an altitude of 1.0 - 3.5 m from the earth's surface.Each sample is taken on 2 sequentially connected (end-to-end) sorption tubes installed vertically, with the inlet opening down.At expected mass concentrations not exceeding 1 mg/m3, sampling is performed with a volume flow rate of 0.3 dm3/min for 30 minutes. If the expected mass concentrations exceed 1 mg/m3, several samples are taken (2 - 3) with a lower volume flow rate during this time period. | ||||||||||
Isopropylalcohol (2-isopropoxyethanol) | ||||||||||||||||
Diphenyl ether | ||||||||||||||||
Butylcellosolve (2-butoxyethanol) | ||||||||||||||||
Durol (1,2,4,5-tetramethylbenzene) | ||||||||||||||||
1-methoxypropan-2-ol | ||||||||||||||||
1-ethoxypropan-2-ol | ||||||||||||||||
4-methylpentan-2-ol | ||||||||||||||||
Cyclohexane | ||||||||||||||||
Methylbutanoate | ||||||||||||||||
Ethylbutanoate | ||||||||||||||||
Methylpropionate | ||||||||||||||||
Ethylpropionate | ||||||||||||||||
Ethylene glycol (1,2-ethanediol) | ||||||||||||||||
Propylene glycol (1,2-propanediol) | ||||||||||||||||
16 | PND F 13.1:2:3.23-98 (FR.1.31.2015. 20483) | butenes (butene-1, butene-2, isobutene) | syringes | 7-10 times pumping the syringe | - | 5 hours | - | |||||||||
Ethene (ethylene) | ||||||||||||||||
Propene (propylene) | ||||||||||||||||
C1-C5 (saturated hydrocarb.) | ||||||||||||||||
17 | PND F 13.1:2:3.25-99 (FR.1.31.2015.20480) | C2-C5 (unsaturated) (total); | syringes | 7-10 times pumping the syringe | - | 5 hours | - | |||||||||
C1-C10 (saturated) (total) | ||||||||||||||||
Benzene | ||||||||||||||||
Toluene | ||||||||||||||||
Ethylbenzene | ||||||||||||||||
Xylols | ||||||||||||||||
Styrene | ||||||||||||||||
18 | FR.1.31.2011.11269 (M-24) | isocyanates and aromatic amines (aniline, n-nitroaniline, toluylenediisocyanate) | sorption tubes | 5 dm3/min | 60 | - | Collect 2 sampling lines. In each line, there are 2 sequentially connected tubes installed vertically with the sorbent down. | |||||||||
19 | PND F 13.1:2: 3.59-07 (FR.1.31.2013.16458) (M 01-05) | aliphatic saturated hydrocarbons of a kerosene fraction C12-C19 | disposable carbon type sampler | 0.2-0.3 dm3/min | 20-30 | 7 days in refrigerator | - | |||||||||
20 | MUK 4.1.1957-05 | vinyl chloride | at the same time on 2 sorption tubes (sorbent Chromosorb 104) | 0,2 dm3/min | 10 | 3 days in refrigerator | Each air sample is simultaneously sampled into two sorption tubes using 2 samplers.Air is pumped through a narrow opening of the sorption tube, cooled by a refrigerator with ice to 0 °C. | |||||||||
Acetaldehyde | ||||||||||||||||
21 | MUK 4.1.616-96 | formic acid | sorption tubes ST 212 | 5 dm3/min | 20 | 10 days | - | |||||||||
acetic acid | ||||||||||||||||
propionic acid | ||||||||||||||||
butanoic acid | ||||||||||||||||
pentanoic acid | ||||||||||||||||
hexanoic acid | ||||||||||||||||
22 | PND F 13.1:3.68-09 (FR.1.31.2015.19226) | Benzene | Absorption device with a porous plate | 0.5 dm/min. | 20-30 | 3 days in refrigerator | - | |||||||||
Xylene (dimethylbenzene) | ||||||||||||||||
23 | MUK 4.1.632-96 | Ethyltoluene | Absorption device with a porous plate | 0.5 dm/min. | 30 | 1 month in a dark and cool place | - | |||||||||
Propylbenzene | ||||||||||||||||
Pseudocumene (1,2,4-trimethylbenzene) | ||||||||||||||||
Naphthalene | 2 series-connected Richter absorbers | 3 dm3/min | 25 | To capture acetic acid vapors, a glass tube with a diameter of 2 cm and a length of 10 cm filled with potassium hydroxide is placed in front of the aspirator. After sampling, the ends of the absorption vessels are fixed with glass plugs. The shelf life of the sample in test tubes with ground-glass stoppers in a dark and cool place is 1 month. | ||||||||||||
24 | MUK 4.1.619-96 | Methylmercaptan | sorption tube-concentrator (TENAX sorbent) | 1,5 dm3/min | 30 | 3 days in refrigerator | - | |||||||||
Propylmercaptan | ||||||||||||||||
Butylmercaptan | ||||||||||||||||
A mixture of natural mercaptans | ||||||||||||||||
25 | RD 52.04.799-2014 (FR.1.31.2015.19883) | Phenol (hydroxybenzene) | sorption tube ST212 or ST 412 | 5 dm3/min | 30 | 2 days at a temperature of 18°C to 25°C in the dark | - | |||||||||
26 | MUK 4.1.1143-02 | Tiametoxam | filter "Sinyaya lenta" | 4 dm3/min | 5 | in a freezer at a temperature of -12 °C for 30 days, in a refrigerator at 4-6 °C - for 7 days. | - | |||||||||
27 | PND F 13.1:2: 3.71-11 (FR.1.31.2015.21767) | Aluminum | AFA-VP; AFA-HP; AFA-HA | 50 dm3 / min | 20 | 1 month | Sampling is carried out at a height of 1.5 meters from the earth surface, the filter holder should be oriented towards the wind flow. | |||||||||
Barium | ||||||||||||||||
Beryllium | ||||||||||||||||
Vanadium | ||||||||||||||||
Bismuth | ||||||||||||||||
Tungsten | ||||||||||||||||
Iron | ||||||||||||||||
Gallium | ||||||||||||||||
Cadmium | ||||||||||||||||
Cobalt | ||||||||||||||||
Silicon | ||||||||||||||||
Lithium | ||||||||||||||||
PND F 13.1:2: 3.71-11 (FR.1.31.2015.21767) | Magnesium | AFA-VP; AFA-HP; AFA-HA | 50 dm3 / min | 20 | 1 month | Sampling is carried out at a height of 1.5 meters from the earth surface, the filter holder should be oriented towards the wind flow. | ||||||||||
Manganese | ||||||||||||||||
Arsenic | ||||||||||||||||
Copper | ||||||||||||||||
Molybdenum | ||||||||||||||||
Silver | ||||||||||||||||
Nikel | ||||||||||||||||
Tin | ||||||||||||||||
Mercury | ||||||||||||||||
Lead | ||||||||||||||||
Selenium | ||||||||||||||||
Antimony | ||||||||||||||||
Titanium | ||||||||||||||||
Chromium | ||||||||||||||||
Zinc | ||||||||||||||||
28 | RD 52.04.823-2015 (FR.1.31.2016.23399) | formaldehyde | Richter absorption device | 2 dm3/min | 30 | 5 days | - |
№ | № RD | Name of the characteristic being defined | What to sample for | Sampling speed | Sampling time | Shelf life | Note | |||||||||
1 | GOST 33007 | Dust content (mass content) | AFA-VP filter | 10-20 dm3/min | - | - | - | |||||||||
2 | MON F 13.1.33-02 (FR. 1. 31. 2014. 18977) | Ammonia | 2 sequentially connected absorbers with a porous plate | 0,5 dm3/min | - | - | - | |||||||||
3 | M-20 (FR. 1. 31. 2011. 11274) | Inorganic compounds of phosphorus (V) (in terms of diphosphorus pentoxide) | Dual SATA-VP filter (glass sampling tube with the desired spout diameter) | 20 dm3/min | 20 | 3 days | - | |||||||||
4 | M-7 (FR. 1. 31. 2011. 11266) | Aerosol of caustic alkalis ( | Dual SATA-VP filter (glass sampling tube with the desired spout diameter) | 20 dm3/min | 20 | 3 days | - | |||||||||
5 | MON F 13.1.45-03 (FR. 1. 31. 2015. 19221) | Hydrogen fluoride (hydrofluoride) | 3 Richter absorbers connected in series | (12-16) dm3/min | - | - | To prevent the absorption of hydrogen fluoride by a rubber hose, the absorption devices, the sampling tube and the trap are connected end-to-end. Cartridges are pre-filled with fluoroplastic chips, and then a swab of fluorine fiber is inserted. For dry gases with a temperature of less than 80°C, use polyethylene cartridges, more than 80°C-fluoroplastic cartridges. When sampling hydrogen fluoride from wet gases, a heated cartridge is used. Preheating is used to prevent the absorption of hydrogen fluoride by moisture that condenses in the cartridge. Gas consumption in the selection of 0.5-2.5 DM/min and a vacuum of 3.3 to 26.6 kPa. The temperature inside the cartridge should be 160-180°C. | |||||||||
6 | MON F 13.1.42-03 (FR. 1. 31. 2015. 19224) | Hydrogen chloride (hydrochloride) | 2 sequentially connected absorbers with a porous glass plate | 1 dm3/min | 10-30 | 1 day | - | |||||||||
7 | M-3 (FR. 1. 31. 2011. 11281) | Sulfuric acid (aerosol) | Dual AFA-VP filter or AFA-HP (glass sampling tube with the desired diameter of the spout) | 20 dm3/min | 20 | 2 days | - | |||||||||
8 | MON F 13.1.46-04 (FR. 1. 31. 2007. 03828) | Sulfuric acid vapors and sulfur trioxide aerosols (in terms of sulfuric acid) | Glass sampling cassette | (0.5-2.0) dm3 / min | - | - | - | |||||||||
9 | MON F 13.1.34-02 (FR. 1. 31. 2007. 03824) | Hydrogen sulfide (dihydrosulfide) | 4 Richter absorbers connected in series | 0,4 dm3/min | 10-30 min | 1 day (preservation of 0.001% R-rum routine: 5-7 days) | At the end of the sampling, it is necessary to determine the final concentration of alkali in the absorption solution, which should be at least 2 mol/dm3. To do this, 1 cm3 of a solution of sodium hydroxide C(NaOH) = 5 mol/dm3 is titrated with a solution of hydrochloric acid C(Hcl) = 0.5 mol/dm3 in the presence of 1-2 drops of phenolphthalein until the pink color disappears within 1 minute. The volume of hydrochloric acid used for titration (V1) is recorded. To the colorless solution, add 1 drop of methylorange (yellow solution) and continue to titrate with a solution of hydrochloric acid until the transition from yellow to orange color. The volume of hydrochloric acid used for titration of the alkaline solution with methylorange is recorded.< br> the concentration of sodium hydroxide (mol / dm3) is calculated by the formula: C(NaOH) = ((V1 - V2) * C(HCl))/V3 where V1 is the amount of hydrochloric acid used for titrating the alkaline solution sample with the indicator phenolphthalein, cm3; V2 is the amount of hydrochloric acid used for titrating the alkaline solution sample with the indicator methylorangem, cm3; C(HCl) is the mass concentration of hydrochloric acid, C(HCl) = 0.5 mol/Dm3; v3 - the volume of the alkaline solution sample selected for analysis, cm3. If the final concentration of alkali after sampling is less than 2 mol / dm3, the sampling is repeated using an absorption solution with an alkali concentration of 8 mol/dm3. after passing a portion of gas, the absorbers are disconnected from the system and the free processes are closed with plugs. Samples are analyzed on the day of selection or preserved with a 0.001 % solution of rutin (arabino-galactan) for 5-7 days. |
|||||||||
Methylmercaptan (methanethiol) | ||||||||||||||||
10 | FR.1.31.2001.00384 | Carbon (soot) | АФА-ВП-20, АФА-ВП-10 | (1-St.40) dm3/min. | 20 | - | - | |||||||||
11 | MON F 13.1.50-06 (FR. 1. 31. 2015. 19220) | Chlorine | Zaitsev absorption device | 0,25 dm3/min | 20 | 1 day | When sampling in direct light, the absorption device is wrapped in black paper | |||||||||
12 | FR. 1. 31. 2011. 11265 (M-10) | Acrylonitrile (propane-2-ison | sorption tube-concentrator (TENAX sorbent) | 10 dm3/min. | 20 | Can be stored in the refriger | At least 3 samples (2 parallel ones in each). | |||||||||
acetaldehyde (acetic aldehyde, ethanal) | 5 dm3/min | Immediately placed in a chilled container and stored for no more than 2 days | ||||||||||||||
Dichloromethane (Methylene chloride) | 10 dm3/min. | Can be stored in the refrigerator for 2 weeks | ||||||||||||||
dichloroethane | ||||||||||||||||
Tetrachloroethylene (perchloroethylene) | ||||||||||||||||
Trichloroethylene (trichloroethene) | ||||||||||||||||
Carbon tetrachloride (tetrachloromethane) | ||||||||||||||||
Chloroform (trichloromethane) | ||||||||||||||||
Epichlorohydrin (chloromethyloxirane) | ||||||||||||||||
13 | FR.1.31.2011.11272 (M-22) | Butadiene (buta-1,3-diene) | sorption tube-concentrator (TENAX sorbent) | 0,1 dm3/min | 20 | 7 days in refrigerator | Make 1-3 consecutive sampling (2 parallel samples for each selection) | |||||||||
Benzaldehyde | ||||||||||||||||
Methylacetate | ||||||||||||||||
Isopropyl acetate (1-methyethyl acetate) | ||||||||||||||||
n-propylacetate | ||||||||||||||||
isobutylacetate | ||||||||||||||||
N-Butylacetate | ||||||||||||||||
N-Amylacetate | ||||||||||||||||
Isoprene | ||||||||||||||||
N-Hexanol | ||||||||||||||||
2-этилгексанол | ||||||||||||||||
octane-1-ол (н-октиловый спирт) | ||||||||||||||||
Бензиловый спирт (бензилкарбинол) | ||||||||||||||||
Пропионовая кислота | ||||||||||||||||
ФР.1.31.2011.11272 (М-22) | Пентановая к-та (валериановая) | sorption tube-concentrator (TENAX sorbent) | 0,1 дм3/мин | 20 | 7 дней в холодильнике | Производят 1-3 последовательных отбора проб (по 2 параллельных пробы для каждого отбора) | ||||||||||
Hexaneовая к-та (капроновая) | ||||||||||||||||
2-ethoxyethyl ether of acetic acid | ||||||||||||||||
Methylcellosolve (2-methoxyethanol) | ||||||||||||||||
Изопрпилцеллозольв (2-изопропоксиэтанол) | ||||||||||||||||
Дифениловый эфир | ||||||||||||||||
Butylcellosolve (2-butoxyethanol) | ||||||||||||||||
Durol (1,2,4,5-tetramethylbenzene) | ||||||||||||||||
1-methoxypropan-2-ol | ||||||||||||||||
1-ethoxypropan-2-ol | ||||||||||||||||
4-methylpentan-2-ol | ||||||||||||||||
Cyclohexane | ||||||||||||||||
Methylbutanoate | ||||||||||||||||
Ethylbutanoate | ||||||||||||||||
Methylpropionate | ||||||||||||||||
Ethylpropionate | ||||||||||||||||
Ethylene glycol (1,2-ethanediol) | ||||||||||||||||
Propylene glycol (1,2-propanediol) | ||||||||||||||||
14 | PND F 13.1:2:3.23-98 (FR.1.31.2015. 20483) | butenes (butene-1, butene-2, isobutene) | Цельностеклянный шприц на (50-100)см3 или газовая пипетка на (250-500)см3 | - | - | не более 5 hours | Шприц промывают анализируемым газом 7-10 раз, после этого производят отбор. Газовую пипетку промывают анализируемым воздухом в течение 2-3 мин. со скоростью 0,5-2,0 дм3/мин., равному 7-10 кратному объему, после этого производят отбор перекрывая одновременно оба зажима и выключают аспиратор. | |||||||||
Ethene (ethylene) | ||||||||||||||||
Propene (propylene) | ||||||||||||||||
C1-C5 (saturated hydrocarb.) | ||||||||||||||||
15 | FR.1.31.2004.01259 (AUV 0.005.169 MVI) | Hexane | sorption tube-concentrator (TENAX sorbent) | 0,05-0,1 дм3/мин | 2 мин | 2 недели в холодильни-ке | Отбирают последовательно 3 пробы в течение 20 минут. | |||||||||
Decane | ||||||||||||||||
Acrolein (acrolein aldehyde, prop-2-en-1-al) | ||||||||||||||||
Methylethyl ketone (butane-2-one) | ||||||||||||||||
Acetone (propan-2-one) | ||||||||||||||||
Hexanone (4-methyl-2-pentanone) | ||||||||||||||||
Cyclohexanone | ||||||||||||||||
Benzene | ||||||||||||||||
Isopropylbenzene (cumene) | ||||||||||||||||
O-Xylene (1,2-dimethylbenzene) | ||||||||||||||||
M-,P-Xylols (in total) | ||||||||||||||||
Styrene (ethenylbenzene) | ||||||||||||||||
Toluene (methylbenzene) | ||||||||||||||||
Ethylbenzene | ||||||||||||||||
FR.1.31.2004.01259 (AUV 0.005.169 MVI) | Butan-1-ol | sorption tube-concentrator (TENAX sorbent) | Of 0.05-0.1 dm3/min | 2 min | 2 weeks in the refrigerator | 3 samples are taken seque | ||||||||||
Amyl alcohol (pentanol) | ||||||||||||||||
Isobutanol (2-methylpropan-1-ol) | ||||||||||||||||
Propyl alcohol (propanol) | ||||||||||||||||
Isopentanol (isoamyl alcohol, 3-methyl-1-butanol) | ||||||||||||||||
isopropyl alcohol (propan-2-ol) | ||||||||||||||||
Ethanol (ethyl alcohol) | ||||||||||||||||
Phenol (hydroxybenzene) | ||||||||||||||||
Butylacetate | ||||||||||||||||
Isoamyl acetate | ||||||||||||||||
Vinylacetate (ethenylacetate) | ||||||||||||||||
Ethylcellosolve | ||||||||||||||||
Ethylacetate | ||||||||||||||||
16 | PND F 13.1:2:3.25-99 (FR.1.31.2015.20480) | C2-C5 (unsaturated) (total); | All-glass syringe at (50-100) cm3 or gas pipette at (250-500) cm3 | - | - | no more than 5 hours | The syringe is washed with the analyzed gas 7-10 times, after which the selection is made. The gas pipette is washed with the analyzed air for 2-3 minutes. at a speed of 0.5-2.0 dm3 / min, equal to 7-10 times the volume, then the selection is made by simultaneously closing both clips and turning off the aspirator. | |||||||||
C1-C10 (saturated) (total) | ||||||||||||||||
Benzene | ||||||||||||||||
Toluene | ||||||||||||||||
Ethylbenzene | ||||||||||||||||
Xylols | ||||||||||||||||
Styrene | ||||||||||||||||
17 | FR. 1. 31. 2011. 11278 (M-16) | Formaldehyde | Absorption device with a poro | 1 dm3/min | 20 | 3 days | Glass sampling probe, the spout of which is filled with glass fiber to a height of 10 mm to eliminate the interfering influence of suspended and resinous substances. Sampling is performed simultaneously from two perpendicular holes | |||||||||
18 | FR.1.31.2011.11269 (M-24) | isocyanates and aromatic amines (aniline, n-nitroaniline, toluylenediisocyanate) | 2 series-connected sorption tubes | ПВ: 5 dm3/min | 20 | 2 days | Sampling probe, the spout of which is filled with glass fiber to a height of 10 mm to eliminate the interfering influence of suspended particles. Sampling is performed simultaneously from two holes (2 sampling lines), 2 series-connected tubes are connected vertically with the sorbent down, the gas current passes through the glass granules from the bottom up. | |||||||||
ATM. vozd.: 5 dm3/min | 60 | Sampling is carried out simultaneously on 2 lines, in each line there are 2 sequentially connected sorption tubes installed vertically with the sorbent down. | ||||||||||||||
РЗ: 5 dm3/min | 15 | Sampling is carried out simultaneously on 2 lines, in each line there are 2 sequentially connected sorption tubes installed vertically with the sorbent down. | ||||||||||||||
19 | MON F 13.1:2: 3.59-07 (FR.1.31.2013.16458) (M 01-05) | aliphatic saturated hydrocarbons of a kerosene fraction C12-C19 | disposable carbon type sampler | 0.2-0.3 dm3/min | 1-3 samples for 20 min selection. consistently | 7 days in refrigerator | 1-3 samples are taken sequentially for 20 minutes | |||||||||
20 | MON F 13.1.56. -07 (FR.1.31.2013.1643) (M-03-06) | acetic aldehyde | sorption tube-concentrator (TENAX sorbent) | 0,1 dm3/min | 20 | 3 days in a freezer | Before sampling, a gas-air mixture is drawn from the flue using an aspirator with a volume flow rate of 1 DM / min for 5-10 minutes. Then a sorption tube with the remaining parts of the sampling unit is attached end-to-end to the probe. The sorption tube is placed in a container with snow or finely crushed ice so that its ends remain dry, and the aspirator is turned on. Intensive cooling of the tube is necessary to prevent loss of Acetaldehyde due to overshoot. | |||||||||
butanoic acid | ||||||||||||||||
butanoic acid | ||||||||||||||||
hexanoic acid | ||||||||||||||||
21 | MON F 13.1.54-2007 | formic acid | glass tube with dinochrome n or P sorbent | see note | see note | - | Approximate total acid concentration, mg / m3 | Sampling rate, dm3 / min | Sampling time, min | |||||||
acetic acid | up to 50 | 5 | 30 | |||||||||||||
propionic acid | 50 to 200 incl | 4 | 25 | |||||||||||||
butanoic acid | from 200 to 600 on | 3 | 10 | |||||||||||||
pentanoic acid | 600 to 2000 incl | 2 | 5 | |||||||||||||
hexanoic acid | ||||||||||||||||
22 | PND F 13.1:3.68-09 (FR.1.31.2015.19226) | Benzene | absorption device with a porous plate | 0,5 dm3/min | 20 | 3 days in refrigerator | At least 3 samples. Attention: the recommended sampling conditions ensure that the equilibrium concentration of aromatic hydrocarbons in acetic acid is reached at temperatures in the flue or atmospheric air from minus 20° to plus 40°C. Shelf life of samples - 3 days in refrigerator. If it is necessary to store the selected sample for a longer time, the acetic acid concentrate is transferred to a 2 ml glass ampoule and sealed on an alcohol lamp. | |||||||||
Xylene (dimethylbenzene) | ||||||||||||||||
23 | MON F 13.1.8-97 (FR. 1. 31. 2013. 16439) | petrol | disposable carbon type sampler | (0,1-0,2) dm3 / min | Sample volume (0.1-20) dm3 | 7 days | After gas sampling, the VUS samplers are placed in tubes with lapped stoppers and delivered to the laboratory. | |||||||||
Concentration of the substance in gas emissions (mg / m3) | Volume of gas emissions sampled (dm3) | |||||||||||||||
from 1 to 10 | 20 | |||||||||||||||
White spirit | from 10 to 50 | 10 | ||||||||||||||
from 50 to 500 | 3-6 | |||||||||||||||
Pentanoic acid (valeric) | from 500 to 5000 | 0,3-0,6 | ||||||||||||||
from 5000 to 15000 | 0.1 | |||||||||||||||
24 | HDPE F 13.1.6-97 | Kerosene | disposable carbon type sampler | (0.1-0.3) dm3 / min | Sample volume (0.1-20) dm3 | 7 days | After gas sampling, the VUS samplers are placed in tubes with lapped stoppers and delivered to the laboratory. | |||||||||
Concentration of the substance in gas emissions (mg / m3) | Volume of gas emissions sampled (dm3) | |||||||||||||||
from 1 to 10 | 20 | |||||||||||||||
from 10 to 50 | 10 | |||||||||||||||
from 50 to 500 | 3-6 | |||||||||||||||
from 500 to 5000 | 0,3-0,6 | |||||||||||||||
from 5000 to 15000 | 0.1 | |||||||||||||||
25 | FR. 1. 31. 2011. 11270 (M-4) | Mineral oil (oil aerosol) | decontaminated filter blue ribbon | 20 dm3 / min | 20 | 7 days | Each time, the oil used in this process is selected. Stainless steel sampling tube with replaceable tips. 3-5 samples are taken | |||||||||
26 | MON F 13.1.30-02 | Turpentine | disposable carbon type sampler | (0,1-0,3) dm3/min | Sample volume (0.1-20) dm3 | 7 days | After gas sampling, the VUS samplers are placed in tubes with lapped stoppers and delivered to the laboratory. | |||||||||
Concentration of the substance in gas emissions (mg / m3) | Volume of gas emissions sampled (dm3) | |||||||||||||||
from 1 to 10 | 20 | |||||||||||||||
from 10 to 50 | 10 | |||||||||||||||
from 50 to 500 | 3-6 | |||||||||||||||
from 500 to 5000 | 0,3-0,6 | |||||||||||||||
from 5000 to 15000 | 0.1 | |||||||||||||||
27 | MON F 13.1.31-02 | Chromium | AFA-HP-10; AFA-HP-20; cartridges with fiberglass | (10-20) dm3/min | sample volume 300 dm3 | - | - | |||||||||
28 | PND F 13.1:2: 3.71-11 (FR.1.31.2015.21767) | Aluminum | AFA-VP; AFA-HP; AFA-HA | (10-15) dm3/min | 20 | 1 month | - | |||||||||
Barium | ||||||||||||||||
Beryllium | ||||||||||||||||
Vanadium | ||||||||||||||||
Bismuth | ||||||||||||||||
Tungsten | ||||||||||||||||
Iron | ||||||||||||||||
Gallium | ||||||||||||||||
Cadmium | ||||||||||||||||
Cobalt | ||||||||||||||||
Silicon | ||||||||||||||||
Lithium | ||||||||||||||||
Magnesium | ||||||||||||||||
Manganese | ||||||||||||||||
Arsenic | ||||||||||||||||
Copper | ||||||||||||||||
Molybdenum | ||||||||||||||||
Silver | ||||||||||||||||
Nikel | ||||||||||||||||
Tin | ||||||||||||||||
ПНД Ф 13.1:2:3.71-11 (ФР.1.31.2015.21767) | Mercury | AFA-VP; AFA-HP; AFA-HA | (10-15) дм3/мин | 20 | 1 month | |||||||||||
Lead | ||||||||||||||||
Selenium | ||||||||||||||||
Antimony | ||||||||||||||||
Titanium | ||||||||||||||||
Chromium | ||||||||||||||||
Zinc | ||||||||||||||||
29 | ФР.1.31.2004.01258 (МВИ-М-34-04) | Aluminum | AFA-VP; AFA-HP; AFA-HA | (15-30)dm3 | 20 | 1 month | - | |||||||||
Барий | ||||||||||||||||
Beryllium | ||||||||||||||||
Vanadium | ||||||||||||||||
Bismuth | ||||||||||||||||
Tungsten | ||||||||||||||||
Iron | ||||||||||||||||
Cadmium | ||||||||||||||||
Calcium | ||||||||||||||||
Potassium | ||||||||||||||||
Cobalt | ||||||||||||||||
Silicon | ||||||||||||||||
Magnesium | ||||||||||||||||
Manganese | ||||||||||||||||
Copper | ||||||||||||||||
Molybdenum | ||||||||||||||||
Arsenic | ||||||||||||||||
Натрий | ||||||||||||||||
Nikel | ||||||||||||||||
Tin | ||||||||||||||||
Mercury | ||||||||||||||||
Selenium | ||||||||||||||||
Lead | ||||||||||||||||
Antimony | ||||||||||||||||
Titanium | ||||||||||||||||
Chromium | ||||||||||||||||
Zinc | ||||||||||||||||
30 | MON F 13.1.76-15 (FR.1.31.2015.20718) (M 06-0-2015) | Benz (a)pyrene | AFA-VP-20 filters | 20 dm3 / min | 20 min. | - | - |
№ | № RD | Name of the characteristic being defined | What to sample for | Sampling speed | Sampling time | Shelf life | Note | |||
1 | ФР.1.31.2001.00384 | Углерод (сажа) | АФА-ВП-20, АФА-ВП-10 | (1-40) dm3/min | 20 | - | - | |||
2 | GOST R ISO 16017-1 | Acetonitrile | sorption tube-concentrator (TENAX sorbent) | (1-10) dm3/min | - | 8 hours (or sorption tubes are placed in a clean, uncoated, airtight container. | - | |||
Acrylonitrile (prop-2-isonitrile) | ||||||||||
Hexane | ||||||||||
Heptane | ||||||||||
Decane | ||||||||||
Dodecane | ||||||||||
Nonane | ||||||||||
Octane | ||||||||||
Aliphatic saturated hydrocarbons of the gasoline fraction C6-C12 | ||||||||||
Undecane | ||||||||||
Acetone (propan-2-one) | ||||||||||
Methylethyl ketone (Butanone) | ||||||||||
Hexanon | ||||||||||
Diacetone alcohol (4-hydroxy-4-methyl-2-pentanone) | ||||||||||
Cyclohexanone | ||||||||||
Benzene | ||||||||||
Isopropylbenzene (Cumene) | ||||||||||
Xylene (dimethylbenzene) | ||||||||||
GOST R ISO 16017-1 | Pseudocumene (1,2,4-trimethylbenzene) | sorption tube-concentrator (TENAX sorbent) | (1-10) dm3/min | - | 8 hours (or sorption tubes are placed in a clean, uncoated, airtight container. | - | ||||
Styrene (ethenylbenzene) | ||||||||||
Toluene (methylbenzene) | ||||||||||
Ethylbenzene | ||||||||||
Vinyl chloride (chloroethene) | ||||||||||
Dichloromethane | ||||||||||
1.1-dichloroethylene | ||||||||||
Trichloroethane | ||||||||||
Trichloroethylene | ||||||||||
Carbon tetrachloride (tetrachloromethane) | ||||||||||
Chlorobezene | ||||||||||
Chloroform (trichloromethane) | ||||||||||
Butanol | ||||||||||
1.2-dichloroethane | ||||||||||
Isobutanol | ||||||||||
(2-methylpropan-1-ol) | ||||||||||
Метанол (карбинол) | ||||||||||
Amyl alcohol (pentanol) | ||||||||||
Propyl alcohol (propan-1-ol) | ||||||||||
Cyclohexanol (cyclohexyl alcohol) | ||||||||||
Ethanol (ethyl alcohol) | ||||||||||
Phenol (hydroxybenzene) | ||||||||||
Butylacetate | ||||||||||
Dibutylphthalate | ||||||||||
Dimethylphthalate | ||||||||||
Dimethylisophthalate | ||||||||||
Diethylphthalate | ||||||||||
Isobutylacetate | ||||||||||
Methylacetate | ||||||||||
Пропилацетат | ||||||||||
Vinylacetate (Ethenylacetate) | ||||||||||
Ethylacrylate | ||||||||||
Ethylacetate | ||||||||||
3 | ФР.1.31.2011.11272 (М-22) | Дивинил (бута-1,3-диен) | sorption tube-concentrator (TENAX sorbent) | (0,05-0,2) dm3/min | 1-3 пробы в течение 15 минут | 7 дней в холодильнике | - | |||
Benzaldehyde | ||||||||||
Methylacetate | ||||||||||
Isopropyl acetate (1-methyethyl acetate) | ||||||||||
n-propylacetate | ||||||||||
isobutylacetate | ||||||||||
N-Butylacetate | ||||||||||
N-Amylacetate | ||||||||||
Isoprene | ||||||||||
N-Hexanol | ||||||||||
FR.1.31.2011.11272 (M-22) | 2-Ethylhexanol | sorption tube-concentrator (TENAX sorbent) | (0.05-0.2) dm3/min | 1-3 samples within 15 minutes | 7 days in refrigerator | - | ||||
Octan-1-ol (n-oktyl alcohol) | ||||||||||
Benzyl alcohol (benzyl carbinol) | ||||||||||
Propionic acid | ||||||||||
Pentanoic acid (valeric) | ||||||||||
Hexanoic acid (capronic) | ||||||||||
2-ethoxyethyl ether of acetic acid | ||||||||||
Methylcellosolve (2-methoxyethanol) | ||||||||||
Isopropylalcohol (2-isopropoxyethanol) | ||||||||||
Diphenyl ether | ||||||||||
Butylcellosolve (2-butoxyethanol) | ||||||||||
Durol (1,2,4,5-tetramethylbenzene) | ||||||||||
1-methoxypropan-2-ol | ||||||||||
1-ethoxypropan-2-ol | ||||||||||
4-methylpentan-2-ol | ||||||||||
Cyclohexane | ||||||||||
Methylbutanoate | ||||||||||
Ethylbutanoate | ||||||||||
Methylpropionate | ||||||||||
Ethylpropionate | ||||||||||
Ethylene glycol (1,2-ethanediol) | ||||||||||
Propylene glycol (1,2-propanediol) | ||||||||||
4 | PND F 13.1:2:3.23-98 (FR.1.31.2015. 20483) | butenes (butene-1, butene-2, isobutene) | syringes | 7-10 times pumping the syringe | - | 5 hours | - | |||
Ethene (ethylene) | ||||||||||
Propene (propylene) | ||||||||||
C1-C5 (saturated hydrocarb.) | ||||||||||
5 | FR.1.31.2004.01259 (AUV 0.005.169 MVI) | Hexane | sorption tube-concentrator (TENAX sorbent) | 0,05-0,1 dm3/min | 2 min | 2 weeks in a refrigerator | - | |||
Decane | ||||||||||
Acrolein (acrolein aldehyde, prop-2-en-1-al) | ||||||||||
Methylethyl ketone (butane-2-one) | ||||||||||
Acetone (propan-2-one) | ||||||||||
Hexanone (4-methyl-2-pentanone) | ||||||||||
Cyclohexanone | ||||||||||
Benzene | ||||||||||
Isopropylbenzene (cumene) | ||||||||||
O-Xylene (1,2-dimethylbenzene) | ||||||||||
FR.1.31.2004.01259 (AUV 0.005.169 MVI) | M-,P-Xylols (in total) | sorption tube-concentrator (TENAX sorbent) | 0.05-0.1 dm3/min | 2 min | 2 weeks in a refrigerator | - | ||||
Styrene (ethenylbenzene) | ||||||||||
Toluene (methylbenzene) | ||||||||||
Ethylbenzene | ||||||||||
Butan-1-ol | ||||||||||
Amyl alcohol (pentanol) | ||||||||||
Isobutanol (2-methylpropan-1-ol) | ||||||||||
Propyl alcohol (propanol) | ||||||||||
Isopentanol (isoamyl alcohol, 3-methyl-1-butanol) | ||||||||||
isopropyl alcohol (propan-2-ol) | ||||||||||
Ethanol (ethyl alcohol) | ||||||||||
Phenol (hydroxybenzene) | ||||||||||
Butylacetate | ||||||||||
Isoamyl acetate | ||||||||||
Vinylacetate (ethenylacetate) | ||||||||||
Ethylcellosolve | ||||||||||
Ethylacetate | ||||||||||
6 | PND F 13.1:2:3.25-99 (FR.1.31.2015.20480) | C2-C5 (unsaturated) (total); | syringes | 7-10 times pumping the syringe | - | 5 hours | - | |||
C1-C10 (saturated) (total) | ||||||||||
Benzene | ||||||||||
Toluene | ||||||||||
Ethylbenzene | ||||||||||
Xylols | ||||||||||
Styrene | ||||||||||
7 | FR.1.31.2011.11269 (M-24) | isocyanates and aromatic amines (aniline, n-nitroaniline, toluylenediisocyanate) | 2 series-connected sorption tubes ST 412 | 5 dm3/min | 15 | 2 days in refrigerator | 2 sampling lines, each with 2 sequentially connected sorption tubes installed vertically with the sorbent down. | |||
8 | PND F 13.1:2: 3.59-07 (FR.1.31.2013.16458) (M 01-05) | aliphatic saturated hydrocarbons of a kerosene fraction C12-C19 | disposable carbon type sampler | 0,2-0,3 dm3/min | 15 | 7 days in refrigerator | in the period of 15 minutes 3 consecutive samples are taken | |||
9 | MUK 4.1.1957-05 | vinyl chloride | at the same time on 2 sorption tubes (sorbent Chromosorb 104) | 0,2 dm3/min | 10 | 3 days in refrigerator | Each air sample is simultaneously sampled into two sorption tubes using 2 samplers.Air is pumped through a narrow opening of the sorption tube, cooled by a refrigerator with ice to 0 °C. | |||
Acetaldehyde | ||||||||||
10 | MUK 4.1.1143-02 | Tiametoxam | filter "Sinyaya lenta" | 4 dm3/min | 5 | in a freezer at a temperature of -12 °C for 30 days, in a refrigerator at 4-6 °C - for 7 days. | - | |||
11 | FR.1.31.2004.01258 (MVI-M-34-04) | Aluminum | AFA-VP; AFA-HP; AFA-HA | 10 dm3/min | 15 | 1 month | - | |||
Barium | 20 dm3/min | 30 | ||||||||
Beryllium | 20 dm3/min | 30 | ||||||||
Vanadium | 20 dm3/min | 30 | ||||||||
Bismuth | 20 dm3/min | 30 | ||||||||
Tungsten | 20 dm3/min | 15 | ||||||||
Iron | 20 dm3/min | 30 | ||||||||
Cadmium | 20 dm3/min | 30 | ||||||||
Calcium | 20 dm3/min | 15 | ||||||||
Potassium | 20 dm3/min | 20 | ||||||||
Cobalt | 10 dm3/min | 15 | ||||||||
Silicon | 20 dm3/min | 15 | ||||||||
Magnesium | 10 dm3/min | 15 | ||||||||
Manganese | 10 dm3/min | 20 | ||||||||
Copper | 10 dm3/min | 15 | ||||||||
Molybdenum | 20 dm3/min | 30 | ||||||||
Arsenic | 20 dm3/min | 30 | ||||||||
Натрий | 20 dm3/min | 20 | ||||||||
Nikel | 10 dm3/min | 20 | ||||||||
Tin | 20 dm3/min | 30 | ||||||||
Mercury | 20 dm3/min | 20 | ||||||||
Selenium | 20 dm3/min | 30 | ||||||||
Lead | 20 dm3/min | 30 | ||||||||
Antimony | 20 dm3/min | 15 | ||||||||
Titanium | 10 dm3/min | 15 | ||||||||
Chromium | 20 dm3/min | 30 | ||||||||
Zinc | 10 dm3/min | 20 |
№ | № RD | Name of the characteristic being defined | What to sample for | Sampling speed | Sampling time | Shelf life | Note | ||
1 | GOST R ISO 16000-3 | Benzaldehyde (benzoic aldehyde) | cartridges with silica-coated DNFH | 1 dm3/min | 5-60 | 30 days in a refrigerator, no more than 2 days without a refrigerator | - | ||
Dimethyl benzoin aldehyde (2.5-dimethylbenzaldehyde) | |||||||||
Valerian aldehyde (valeraldehyde)) | |||||||||
isovalerian aldehyde | |||||||||
hexanal (caproic aldehyde) | |||||||||
croton aldehyde | |||||||||
the propionic aldehyde (propenal) | |||||||||
o-toluene aldehyde | |||||||||
m-toluene aldehyde | |||||||||
p-toluene aldehyde | |||||||||
acetaldehyde (acetic aldehyde) | |||||||||
butanaldehyde (butanal) | |||||||||
formaldehyde (methanal) | |||||||||
acetone (propan-2-one) | |||||||||
2 | MUK 4.1.1957-05 | vinyl chloride | one sample consists of 2 sorption tubes (Chromosorb 104 sorbent) | 0,2 dm3/min | 10 | 3 days in refrigerator | Air is pumped at a speed of 0.2 dm3/min for 10 minutes through a narrow hole of the sorption tube, cooled by a refrigerator with ice to 0 °C. | ||
Acetaldehyde | |||||||||
3 | GOST R ISO 16000-14 | PCBs (ind.) | sorbent with the applied C13 isotope | - | - | - | - | ||
4 | MUK 4.1.1044 a-01 | Dimethylamine | sorbent with the applied C13 isotope | 0,2 dm3/min | 10 | 3 days | Air is aspirated through a pre-cooled to 0°C outlet of a sorption tube. | ||
Diethylamines | |||||||||
Propylamines | |||||||||
Triethylamines | |||||||||
Ethylamines | |||||||||
Dimethylformamide | |||||||||
5 | GOST R ISO 16017-1 | Acetonitrile | sorption tube-concentrator (TENAX sorbent) | (1-10) dm3/min | - | 8 hours (or sorption tubes are placed in a clean, uncoated, airtight container. | - | ||
Acrylonitrile (prop-2-isonitrile) | |||||||||
Hexane | |||||||||
Heptane | |||||||||
Decane | |||||||||
Dodecane | |||||||||
Nonane | |||||||||
Octane | |||||||||
Aliphatic saturated hydrocarbons of the gasoline fraction C6-C12 | |||||||||
Undecane | |||||||||
Acetone (propan-2-one) | |||||||||
Methylethyl ketone (Butanone) | |||||||||
Hexanon | |||||||||
Diacetone alcohol (4-hydroxy-4-methyl-2-pentanone) | |||||||||
Cyclohexanone | |||||||||
Benzene | |||||||||
Isopropylbenzene (Cumene) | |||||||||
Xylene (dimethylbenzene) | |||||||||
Pseudocumene (1,2,4-trimethylbenzene) | |||||||||
Styrene (ethenylbenzene) | |||||||||
Toluene (methylbenzene) | |||||||||
Ethylbenzene | |||||||||
Vinyl chloride (chloroethene) | |||||||||
Dichloromethane | |||||||||
1.1-dichloroethylene | |||||||||
Trichloroethane | |||||||||
Trichloroethylene | |||||||||
GOST R ISO 16017-1 | Carbon tetrachloride (tetrachloromethane) | sorption tube-concentrator (TENAX sorbent) | (1-10) dm3/min | - | 8 hours (or sorption tubes are placed in a clean, uncoated, airtight container. | - | |||
Chlorobezene | |||||||||
Chloroform (trichloromethane) | |||||||||
Butanol | |||||||||
1.2-dichloroethane | |||||||||
Isobutanol | |||||||||
(2-methylpropan-1-ol) | |||||||||
Метанол (карбинол) | |||||||||
Amyl alcohol (pentanol) | |||||||||
Propyl alcohol (propan-1-ol) | |||||||||
Cyclohexanol (cyclohexyl alcohol) | |||||||||
Ethanol (ethyl alcohol) | |||||||||
Phenol (hydroxybenzene) | |||||||||
Butylacetate | |||||||||
Dibutylphthalate | |||||||||
Dimethylphthalate | |||||||||
Dimethylisophthalate | |||||||||
Diethylphthalate | |||||||||
Isobutylacetate | |||||||||
Methylacetate | |||||||||
Пропилацетат | |||||||||
Vinylacetate (Ethenylacetate) | |||||||||
Ethylacrylate | |||||||||
Ethylacetate | |||||||||
6 | PND F 13.1:2:3.23-98 (FR.1.31.2015. 20483) | butenes (butene-1, butene-2, isobutene) | syringes | 7-10 times pumping the syringe | - | 5 hours | - | ||
Ethene (ethylene) | |||||||||
Propene (propylene) | |||||||||
C1-C5 (saturated hydrocarb.) | |||||||||
7 | GOST 17.2.4-05 | suspended substances (dust) | AFA-VP filter | 75 dm3/min | At the end of sampling the total volume of air passed is recorded. | - | - | ||
8 | GOST ISO 16000-6 | 1,2,3-trimethylbenzene | sorption tube-concentrator (TENAX sorbent) | from 50 to 200 ml3/min | from 25 to 100 min | 4-weeks from the sampling date | - | ||
1,2,4-trimethylbenzene | |||||||||
benzene | |||||||||
Ethylbenzene | |||||||||
Isopropylbenzene | |||||||||
m -, p-Xylenes (sum) | |||||||||
o-xylene | |||||||||
Styrene | |||||||||
Toluene (methylbenzene) | |||||||||
1-butanol | |||||||||
1-pentanol | |||||||||
1-propanol | |||||||||
2-methyl-1-propanol (isobutanol) | |||||||||
cyclohexanol | |||||||||
Phenol (hydroxybenzene) | |||||||||
Acetaldehyde | |||||||||
2-butanone (methylethyl ketone) | |||||||||
acetone | |||||||||
cyclohexanone | |||||||||
1,1,1-trichloroethane | |||||||||
1,1,2-trichloroethane | |||||||||
1,2-dichloroethane | |||||||||
Carbon tetrachloride (tetrachloromethane) | |||||||||
Chlorobezene | |||||||||
Dichloromethane | |||||||||
trichloromethane | |||||||||
tetrachloroethene | |||||||||
trichloroethene | |||||||||
Butylacetate | |||||||||
Ethylacetate | |||||||||
Ethylacrylate | |||||||||
isobutylacrylate | |||||||||
metthyakrylate | |||||||||
methylmethacrylate | |||||||||
Propylacetate | |||||||||
Vinylacetate (Ethenylacetate) | |||||||||
Dibutylphthalate | |||||||||
Dimethylphthalate | |||||||||
hexane | |||||||||
GOST ISO 16000-6 | heptane | sorption tube-concentrator (TENAX sorbent) | from 50 to 200 ml3/min | from 25 to 100 min | 4-weeks from the sampling date | - | |||
octane | |||||||||
nonane | |||||||||
decane | |||||||||
undecane | |||||||||
dodecane | |||||||||
amount of SVOS | |||||||||
amount of VVOC | |||||||||
TVOC in toluene equivalent |