Name of the index |
Material of the sample container |
Method of storage and conservation |
Volume |
Maximum recommended storage period |
Recommended location of measurement |
Note |
Hydrogen index |
Polymer material or glass |
- |
a minimum of 2.0 dm3 (2 liters) |
- |
At the sampling site |
Measurement should be done as soon as possible after sampling |
Transporting at temperatures below the sampling temperature |
6 hours |
Laboratory |
||||
Total mineralization, dry residue |
Polymer material or glass |
Cooling to 2°C - 5°C |
24 hours |
Laboratory |
- |
|
Total hardness |
Polymer material or glass |
- |
24 hours |
Laboratory |
Storage is allowed for 48 hours, except for samples with a specific electrical conductivity of more than 70 mcSm/m.It is not allowed to use sulfuric acid. |
|
Permanganate oxidability |
Glass |
Acidification to a pH of less than 2 with sulfuric acid, cooling to 2°C - 5°C and storage in a dark place |
2 days |
Laboratory |
Measurement should be done as soon as possible |
|
Polymeric material |
Freezing to minus 20°C |
1 month |
Laboratory |
|||
Acidity and alkalinity |
Polymer material or glass |
Cooling to 2°C - 5°C |
24 hours |
Laboratory |
It is preferable to perform measurements at the sampling site (especially for samples with a high concentration of dissolved gases) |
|
Specific conductivity |
Polymer material or glass |
Cooling to 2°C - 5°C |
24 hours |
Laboratory |
Measurement should be done as soon as possible.It is preferable to perform measurement at the sampling site |
|
Suspended solids content |
Polymer material or glass |
- |
24 hours |
Laboratory |
Measurement should be done as soon as possible |
|
Ammonia and ammonium ions (total) |
Polymer material or glass |
Acidification with sulfuric acid to pH less than 2, cooling to 2°C - 5°C |
24 hours |
Laboratory |
- |
|
Cooling to 2°C - 5°C |
6 hours |
Laboratory |
||||
Nitrogen of organic compounds |
Polymer material or borosilicate glass |
Acidification with sulfuric acid to a pH less than 2, cooling to 2°C - 5°C and storage in a dark place |
24 hours |
Laboratory |
Acidification is not performed if the same sample is used to determine ammonia |
|
Bromides and inorganic bromine compounds |
Polymer material or glass |
Cooling to 2°C - 5°C |
24 hours |
Laboratory |
Samples should be protected from direct sunlight |
|
Hydrocarbonates |
Polymer material or glass |
Cooling to 2°C - 5°C |
24 hours |
Laboratory |
- |
|
Nitrates |
Polymer material or glass |
Filtration through a membrane filter with a pore size of 0.45 microns and cooling to 2°C - 5°C |
48 hours |
Laboratory |
- |
|
Nitrites |
Polymer material or glass |
Cooling to 2°C - 5°C |
24 hours |
Laboratory |
- |
|
Silicates (dissolved), silicates (total) |
Polymeric material |
Filtration and acidification with sulfuric acid to pH less than 2 and cooling to 2°C - 5°C |
24 hours |
Laboratory |
- |
|
Sulphates |
Polymer material or glass |
Cooling to 2°C - 5°C |
7 days |
Laboratory |
- |
|
Organic carbon |
Polymer material or glass |
Cooling to 2°C - 5°C and storage in a dark place |
7 days |
Laboratory |
- |
|
Fluorides |
Polymeric material |
- |
1 month |
Laboratory |
- |
|
Chlorides |
Polymer material or glass |
- |
1 month |
Laboratory |
- |
|
Chromaticity |
Polymer material or glass |
- |
6 hours |
Laboratory |
- |
|
Cooling to 2°C - 5°C and storage in a dark place |
24 hours |
Laboratory |
||||
Turbidity |
Polymer material or glass |
- |
24 hours |
Laboratory |
- |
|
Odor |
Polymer material or glass |
Cooling to 2°C - 5°C |
6 hours |
Laboratory |
It is allowed to measure at the sampling site |
|
Specific conductivity |
Polymer material or glass |
Cooling to 2°C - 5°C |
24 hours |
Laboratory |
Measurement should be done as soon as possible.It is preferable to perform measurement at the sampling site |
|
Suspended solids content |
Polymer material or glass |
- |
24 hours |
Laboratory |
Measurement should be done as soon as possible. |
|
Ammonia and ammonium ions (total) |
Polymer material or glass |
Acidification with sulfuric acid to pH less than 2, cooling to 2°C - 5°C |
24 hours |
Laboratory |
- |
|
Cooling to 2°C - 5°C |
6 hours |
Laboratory |
||||
Nitrogen of organic compounds |
Acidification with sulfuric acid to pH less than 2, cooling to 2°C - 5°C |
Cooling to 2°C - 5°C |
24 hours |
Laboratory |
- |
|
Oxygen |
Polymer material or glass |
- |
- |
At the sampling site |
- |
|
Polymeric material |
Oxygen fixation is performed in accordance with the requirements of specific methods for determining the index |
4 days |
Laboratory |
Oxygen fixation is performed in accordance with the requirements of specific methods for determining the index |
||
Taste |
Polymer material or glass |
- |
6 hours |
Laboratory |
The determination is carried out in the absence of suspicion of bacterial contamination and the absence of substances in dangerous concentrations |
|
Metals |
Polymeric material |
Acidification to pH less than 2 |
0.25 dm3 (0.25 l.) |
1 month |
Laboratory |
- |
Metals (dissolved forms) |
Polymeric material |
Filtration and acidification of filtrate with nitric acid to pH less than 2 |
1 month |
- |
||
BOD (biochemical oxygen demand) |
Glass |
- |
1,0 дм³ (1 л.) |
24 ч |
Laboratory |
- |
COD(chemical oxygen demand) |
Glass |
Cooling to 2°C - 5°C and storage in a dark place |
5 days |
- |
||
Mercury |
Glass |
Acidification to pH less than 2 |
0.1 dm3 (0.1 l.) |
1 month |
Laboratory |
- |
Fats, oils, and hydrocarbons |
Glass |
Add the substance used for extraction (if possible) at the sampling site and cooling to 2°C-5°C |
1.0 dm3 (1 l.) |
24 hours |
Laboratory |
- |
Benz(a)pyrene |
Glass |
Adding the solvent used for extraction; storage at a temperature of 2°C-5°C. If active chlorine is present, add 20 mg of sodium thiosulfate per 1 liter of sample |
1.0 dm3 (1 l.) |
1 days |
Laboratory |
Sample extraction is carried out no later than 1 day from the moment of sampling |
Oil and petroleum products (total) |
Glass |
Add the substance used for extraction (if possible on site) and cool to 2°C-5°C |
1.0 dm3 (1 l.) |
24 hours |
Laboratory |
- |
Organic chlorine compounds (organochlorine compounds) |
Glass |
Cooling to 2°C - 5°C and storage in a dark place |
1.0 dm3 (1 l.) |
3 days |
Laboratory |
Measurement should be done as soon as possible |
Pesticides (organic compounds containing chlorine) |
Glass |
Adding a substance used for extraction by a specific method of determination; cooling to 2°C - 5°C and storing in a dark place |
1.0 dm3 (1 l.) (1 л.) |
5 days |
Laboratory |
- |
Pesticides (organic compounds containing phosphorus) |
Glass |
Cooling to 2°C - 5°C and storage in a dark place |
1.0 dm3 (1 l.) (1 л.) |
24 hours |
Laboratory |
- |
Surfactants (cationic) |
Glass |
Cooling to 2°C - 5°C |
0.1 dm3 (0.1 l.) |
48 hours |
Laboratory |
- |
Surfactants (anionic) |
Glass |
Cooling to 2°C - 5°C |
48 hours |
- |
||
Adding 2-4 cm3 ³ chloroform per 1 dm3 ³ sample and cooling to 2°C - 5°C |
7 days |
|||||
Surfactants (non-ionic) |
Glass |
Cooling to 2°C - 5°C |
1 month |
- |
||
Sulfides (including volatile ones) |
Polymer material or glass |
Adding sodium carbonate followed by adding zinc acetic acid in quantities depending on the method of determination |
0.5 dm3 (0.5 l.) |
24 hours |
Laboratory |
Containers with samples are filled to the top.Measurement should be done as soon as possible |
Phenols |
Glass |
Cooling to 2°C - 5°C and storage in a dark place. |
1.0 dm3 (1 l.) (1 л.) |
24 hours |
Laboratory |
- |
Chlorophyll |
Polymer material or glass |
Cooling to 4°C |
1.0 dm3/Filters |
24 hours |
Laboratory |
When transporting the container is placed in a dark place |
Filtration and freezing of precipitate |
1 month |
When transporting the container is placed in a dark place |
||||
Chloroform and other volatile halogenorganics |
Glass |
Storage at 2°C - 5°C |
1.0 dm3 (1 l.) (1 л.) |
48 hours |
Laboratory |
- |
Alpha activity, beta activity |
Polymeric material |
- |
A 5.0 dm3 (5 l.) |
Quickly as possible |
Laboratory |
- |
Isotopes of radon.Radium by radon |
Polymeric material |
Cooling to 2°C - 5°C |
As quickly as possible, but no more than 48 hours, due to the short half-life |
- |
||
Radium |
Polymeric material |
- |
Quickly as possible |
- |
||
Radioactive strontium |
Polymeric material |
- |
As quickly as possible within 14 days. |
- |
Call us:
send us an email
Leave a request using the form